What the cold here does to a heat pump
Winter in Saginaw County is long and it bites. The heat runs about eight months a year, October through May, and the overnight low averages 19°F across December, January and February. That is below both of the marks that matter for a heat pump. Below 40°F a standard heat pump puts out less than its rated heating capacity. Below about 35°F it often needs backup heat to make up the difference. The average winter night here is under both marks, and so is every single one of the roughly 145 nights a year that drop to freezing or below.
That doesn't mean a heat pump quits. On about 8 nights a year here the temperature falls to 0°F or below, and a cold-climate heat pump, the kind built and tested to hold up in hard cold, still makes heat at that mark. A two-winter study of prototype cold-climate heat pumps in occupied homes found backup heat covered only a small share of the load between 0°F and 35°F, and running on backup alone was rare even at 0°F. The federal Cold Climate rating requires a heat pump to still produce 1.75 units of heat per unit of electricity at 5°F, and hold onto 70 percent of its 47°F capacity at that temperature. So the honest answer is that a heat pump can heat a Saginaw County home through the winter, but only a cold-climate model is built for the nights that actually happen here. A standard heat pump, at federal minimum efficiency, is matched against this cold for over half the nights of the entire heating season.