Can a heat pump keep up on the coldest nights here
Winter here is the whole question. Heat runs about eight months a year, October through May, and the overnight low averages 19°F across December, January and February. About 150 nights a year drop to freezing or below, over half the nights the heat is running at all. A standard heat pump starts losing ground before it even gets that cold. Below 40°F it puts out less heat than its rating says. Below about 35°F it typically needs backup heat to make up the difference. At 19°F, the average winter night here, a standard heat pump is well past both marks. So is every one of those 150 freezing nights.
That does not mean a heat pump cannot heat a house here. It means a standard one is working below its rating most of the winter, and leaning on backup heat to make up the rest. A cold climate model is built for this. To earn the ENERGY STAR Cold Climate label, a heat pump has to deliver at least 1.75 units of heat per unit of electricity at 5°F, and hold onto at least 70 percent of its 47°F capacity at that same temperature. That is well below the 19°F average here. In a two-winter field test of prototype cold climate heat pumps in occupied homes, backup heat covered only a small share of the load between 0°F and 35°F, and the home running on backup heat alone was rare even above 0°F. The county only sees about 10 nights a year at 0°F or colder. A cold climate heat pump is built for nights colder than almost anything Genesee County sees.