What the cold does to a heat pump here
Winters here are long and they get genuinely cold. Heat runs about eight months a year, October through May, and the overnight low averages 20°F across December, January and February. About 135 nights a year dip to freezing or below, over half the nights in that eight month stretch. That is the weather a heat pump has to work in, not the mild stretches around it.
A standard heat pump starts losing ground before it even gets that cold. Below 40°F its heat output falls short of what it is rated for. Below about 35°F it often needs backup heat to keep up. The average winter night here is 20°F, under both marks, and every single one of those 135 freezing nights is under both marks too. This is not a once-a-year cold snap problem. It is most of the winter.
Only about 5 nights a year hit 0°F or below, so the deep cold is rare here. That matters because it means the real question is not whether your house can survive a handful of brutal nights. It is what a standard heat pump is doing on the ordinary cold nights that make up most of the season, and on those nights it is running under its rating and often leaning on backup heat.
A cold climate heat pump is built for exactly this. To earn that label it has to prove, through third party testing, that it still makes at least 1.75 units of heat for every unit of electricity at 5°F and holds onto at least 70 percent of its 47°F capacity at that temperature. In field tests of prototype cold climate models placed in occupied homes, backup heat covered only a small share of the heating between 0°F and 35°F, and running on backup alone was rare even above 0°F. If a heat pump is the choice for this county, that rating is what makes it hold up, not the standard equipment.