What the cold here does to a heat pump
Winters in Tuscola County decide this. The overnight low averages 18°F across December, January and February, and that's the average, not the exception. About 150 nights a year here drop to freezing or below, more than half the nights across the eight months your heat runs.
A standard heat pump starts losing ground before it even gets that cold. Below 40°F it puts out less heat than its rating says. Below about 35°F it often needs backup heat to keep up. Eighteen degrees is below both marks, and every one of those 150 freezing nights is too. This isn't a machine that struggles on the coldest night of the year. It's working under its rating most of the winter.
There's a version built for this. Heat pumps carrying the ENERGY STAR Cold Climate mark are tested to hold at least 70 percent of their rated heat at 5°F, and a two-winter field test of these in occupied homes found backup heat covered only a small share of the output between 0°F and 35°F. That's a different machine than the federal-minimum one priced in the band above. If a heat pump is going in this county, that's the one to ask for.
Your furnace season runs eight months, October through May. A gas furnace doesn't lose capacity in the cold the way a heat pump does. It's sized for the load and it delivers it whether it's 18°F or minus 5, which is where its edge shows most on the roughly 11 nights a year that reach 0°F or below.