What the cold does to a heat pump here
Winter nights in Allegan County average 20°F, and a standard heat pump starts losing ground well before that. Below 40°F it puts out less heat than its rating says. Below about 35°F it usually needs backup heat to make up the difference. Your overnight low here sits under both marks all winter, and about 140 nights a year, over half the nights the heat runs, drop to freezing or below.
That doesn't mean the heat pump can't keep the house warm. It means it's not doing it alone on those nights. The backup is almost always electric resistance heat, the same expensive way a space heater makes heat, and it's what pushes the running cost up. Six nights a year here reach 0°F or colder. A standard heat pump leans hardest on backup right around there.
If you want a heat pump and want to limit how often it falls back to resistance heat, the ENERGY STAR Cold Climate models are built for exactly this. To earn that label a heat pump has to keep at least 70 percent of its 47°F heating capacity once it hits 5°F, and still produce real heat efficiently at that temperature. Field testing on homes running prototype cold-climate heat pumps found backup heat carried only a small share of the load between 0°F and 35°F, and running on backup alone was rare even at 0°F. That's a different machine than the federal-minimum unit the running-cost numbers above are built on.