Ten months of run time
Furnaces in Marquette County run from September through June, with overnight lows averaging 9°F in December, January and February. That is ten months asking a lot of the same igniter, blower and heat exchanger.
Takes about a minute. No obligation.
Furnaces in Marquette County run from September through June, with overnight lows averaging 9°F in December, January and February. That is ten months asking a lot of the same igniter, blower and heat exchanger.
A furnace running nearly year round shows its weak points early. Checking it before September means catching a cracked igniter or a dirty flame sensor on your terms, not at 9 below.
Gas in Michigan runs $10.21 per million Btu.
A furnace that skips its tune-up burns more of it to do the same job.



September is when heat starts here, and it runs clear through to June. That is ten months of work for the igniter, the blower and the heat exchanger. August is the month to get a contractor out, while the furnace is still off and nothing depends on it yet. Whatever is going to fail has ten months to do it, and it is easier to find a cracked heat exchanger or a weak igniter before the furnace is asked to run.
Most homes here heat with gas, and almost all the rest run on propane. Both burn fuel, which means both need a burner that lights clean, a vent that draws right, and safety controls that shut the furnace down if something is off. A filter change does not touch any of that. A tune-up does.
Find a contractor
A dirty filter is where most of this starts. Air has to move through it to get to the heat exchanger, and when it's clogged the blower works harder to pull it through. That raises the heat exchanger's temperature past what it's built for, and that is what eventually cracks it. A furnace with a cooling coil in the same cabinet can get fouled there too, and a dirty coil chokes airflow the same way a dirty filter does. The drain only matters if the furnace condenses, which the high efficiency ones do. That line clogs with scale and sediment, and when it backs up the furnace shuts itself down rather than overflow. Checking the filter, the coil and the drain does not take long. Left alone, all of them get worse.
Pull the filter and hold it to a light. If you can't see light through it, it's done. A furnace with a clogged filter pulls harder to move the same air, and that strain is what wears out a blower motor early. Check it monthly during the heating months and swap it when it's dirty, not on a schedule.
The igniter, the heat exchanger and the gas valve are behind a panel for a reason. Opening that cabinet and probing around can knock a wire loose or crack a part that was fine before you touched it. Keep the area around the furnace clear so air can reach it, and leave what's inside the cabinet for a contractor to handle.
A flame sensor looks fine and still fails. It builds a film over time that only shows up as a weak signal, and that's what makes the furnace shut off a few seconds after it lights. You won't see that film without pulling the sensor and cleaning it. A pressure switch is the same kind of problem. It reads the draft through a small hose, and if that hose has a pinhole or a bit of condensation sitting in it, the switch gets a false reading and won't let the furnace start at all. Heat exchangers crack from the inside, where the flame actually touches metal, and that side is never visible with the cabinet closed. None of this shows up as a smell or a sound ahead of time. It shows up as a furnace that won't run.
A tune-up starts with the burners. They need to light in a clean row of flames, even and blue, not yellow or ragged at the tips. A flame that's lifting off the burner or rolling back on itself is burning the gas wrong, and that shows up later as soot inside the heat exchanger. The technician checks the gas pressure at the valve, because too much or too little changes how that flame behaves no matter how clean the burner is. The blower gets checked too, for the amount of air it's actually moving, not just whether it spins. A blower wheel caked with dust moves less air than it's rated for, and that changes the furnace's temperature rise the same way a dirty filter does. The limit switch gets tested last. It shuts the furnace down if it overheats, and the flue has to carry exhaust out of the house instead of back into it.