Eight months of work
Furnaces in Bay City run from October through May. Overnight lows average 18°F in December, January and February, so the furnace is holding that line most nights, not just taking the edge off.

Takes about a minute. No obligation.
Furnaces in Bay City run from October through May. Overnight lows average 18°F in December, January and February, so the furnace is holding that line most nights, not just taking the edge off.
A furnace running eight months a year wears its igniter, blower motor and other parts sooner than one that only runs a few months. Problems that would take years to show up elsewhere show up here faster.
Almost 8 in 10 homes in Bay County heat with utility gas.
A gas furnace needs its burner, venting and safety controls checked every year, not just a new filter.



Half the homes in Bay County were built in 1963 or earlier. The ductwork and venting in a house that age usually date back to the house itself, even if the furnace was swapped out at some point. A furnace that old develops small issues gradually. A blower motor starts running louder than it used to. An igniter takes an extra try to light. A yearly check catches those while they're still small. Skip a few years and the same problems tend to show up as a no-heat call in the middle of winter.
Furnaces here start running in October and keep going through May. September is the month before that starts, while the furnace is sitting idle and a tech can look it over without the house needing heat yet. Catch a worn igniter or a tired blower motor on a bench in September, before eight months of work finds it instead.
Find a contractor
Once October hits, the furnace doesn't get a day off until spring. There's no mild stretch in the middle where it can idle and a tech can get to it easily. Get the igniter and blower checked before the season starts, not during it.
A furnace left alone collects dust on the blower wheel and burner assembly. The blower has to work harder to push the same air, and a dirty flame sensor starts misreading the flame and shutting the burner off. None of this breaks the furnace outright. It just makes every part of the system work harder than it should, for longer, until something gives out.
The igniter and flame sensor take the direct hit from heat and combustion every time the furnace cycles on, so they tend to be the first parts to fail when nobody's checked them. A furnace that skips its yearly check usually finds out one of them is bad on a cold night, in the middle of a heating cycle, instead of during an inspection where a tech can see it coming.
A furnace doesn't have a drain or coils to worry about, that's the air conditioner's job, but the filter still runs the whole show. A dirty filter chokes the air coming back to the furnace, so the blower pulls harder to move the same amount through the house. That strain shows up in the blower motor first, and it's also what lets dust reach the burner assembly and the flame sensor, since a clogged filter forces more air to find its way around the edges instead of through the paper. A filter is the one part of this system meant to be changed, not fixed, and it's the cheapest thing in the furnace by far. Leave it too long and every other part works harder to make up for it.
A tune-up starts with the burner assembly, pulled and cleaned if soot or dust has built up on it, because a dirty burner burns unevenly and that uneven flame is what fouls a flame sensor early. The igniter gets checked for a weak glow or a crack, since it's the part that fails first on a furnace nobody's looked at in a year. A tech checks the heat exchanger for cracks, which matters more than almost anything else in the cabinet because a cracked exchanger can let exhaust mix into the air the blower pushes through the house. The venting gets checked for a solid connection and a clear path outside, and the blower wheel gets cleaned if it's caked with dust, since a dirty wheel moves less air no matter how hard the motor spins. Gas pressure gets tested against what the furnace is built to run on. Last, the control board and safety switches get run through their paces, because those are what shut the furnace down safely when something else goes wrong, and they only help if they're working themselves.