What winter here does to a heat pump
Your furnace or heat pump spends October through May working in this county. That is eight months of heating against three of cooling, June through August. Whichever machine you choose, heating is most of its job here, not cooling.
A standard heat pump starts falling behind before the real cold arrives. Below 40°F it already makes less heat than its rating says. Below about 35°F it often needs backup heat to make up the difference. The average overnight low here across December, January and February is 21°F, under both marks. About 125 nights a year drop to freezing or below, roughly half the nights the heat runs, and every one of them is colder than both the 40°F and 35°F lines.
That is not the whole story. A heat pump built to the ENERGY STAR Cold Climate spec has to deliver at least 1.75 units of heat per unit of electricity at 5°F and hold onto 70 percent of its warm-weather capacity at that temperature, checked by independent testing, not the manufacturer. A two-winter field test of these units in real homes found backup heat covering only a small share of the load between 0°F and 35°F, and the units running on backup alone was rare even above 0°F. Only about 4 nights a year here reach 0°F. A cold-climate heat pump is built for the cold this county actually has. A standard one is not.