What the cold actually does to a heat pump here
Your winters are the whole question. The overnight low averages 19°F across December, January and February, and the heat runs eight months a year here, October through May. A standard heat pump starts losing ground before it even gets that cold. Below 40°F it puts out less heat than its rating says. Below about 35°F it usually needs backup heat to keep up. Both of those marks sit above your winter average, not below it. Every night here at or below freezing, about 140 of them a year, is colder than both marks.
That doesn't mean a heat pump leaves you cold. It means a standard one is working below its best range most nights for eight months, and needs backup on a lot of them. An ENERGY STAR Cold Climate heat pump is built for this. To earn that label it has to keep making real heat at 5°F, at least 1.75 units of heat for every unit of electricity, and hold onto most of its capacity at that temperature, tested by someone other than the manufacturer. In a two-winter study of these cold-climate models running in real houses, backup heat only filled in a small share of what was needed between 0°F and 35°F, and running on backup alone was rare even at 0°F. That is the gap between what a basic heat pump does in your winters and what the ones built for cold climates do.
The six nights a year that hit 0°F or below are the real edge case, not the normal one. Most of your cold nights, the 140 or so at or below freezing, sit well above that. A cold climate heat pump is built to keep working through both.