Can a heat pump handle winter here
Your winter nights average 20°F, and about 140 of them drop to freezing or below. A standard heat pump starts losing capacity below 40°F and often needs backup heat below about 35°F. That means almost every cold night here, your heat pump is working below the point where it performs at its rating.
This doesn't mean it stops. It means it needs help on those nights, usually electric resistance coils, to make up the difference. That backup heat costs more to run than the heat pump itself, and a lot more than a furnace. Only about 4 nights a year here hit 0°F, so the deep cold is rare. It's the ordinary 20 to 32°F nights, the bulk of your winter, where a standard heat pump is already short of its rated output.
If you want a heat pump to carry the house through a Muskegon winter, it needs to be built for it. The ENERGY STAR Cold Climate mark requires a heat pump to still make 1.75 units of heat per unit of electricity at 5°F, and hold onto at least 70 percent of its 47°F capacity at that same temperature, checked by independent testing. That is a different machine than the federal minimum unit priced in the running-cost comparison above. Field testing on cold-climate models backs this up: over two winters in occupied homes, backup heat covered only a small share of the heat needed between 0°F and 35°F, and the homes almost never ran on backup heat alone unless it was below 0°F.