What the cold here does to a heat pump
Winter here is long and it gets genuinely cold. Heat runs about eight months a year, October through May, and the overnight low averages 18°F across December, January and February. That 18°F average matters more than it sounds like it should, because a standard heat pump starts falling short of its rated heat output below 40°F, and often needs backup heat below about 35°F. An average night here is below both marks.
It is not just the average night. About 140 nights a year here drop to freezing or below, more than half of the nights across the whole heating season. Every one of those nights is already past the point where a standard heat pump is working at a disadvantage. Only about 7 nights a year reach 0°F or below, so the deep cold is rare, but the ordinary cold that gives a standard heat pump trouble is not rare here. It is most of the winter.
A heat pump built to carry the ENERGY STAR Cold Climate label is a different machine. To earn that label it has to keep making real heat down to 5°F, at least 1.75 units of heat for every unit of electricity, and hold onto at least 70 percent of its warm-weather capacity at that temperature. Field testing on prototype cold-climate heat pumps backs this up in practice: over two winters in occupied homes, backup heat only covered a small share of the load between 0°F and 35°F, and the home rarely ran on backup alone even above 0°F. A standard heat pump in a Midland County winter leans on backup heat often. A cold-climate one mostly does not.