What winter here does to a heat pump
Kent County winters put a heat pump to work at exactly the temperatures where it struggles most. The overnight low here averages 19°F across December, January and February, and that's below both marks that matter for a standard heat pump: below 40°F it puts out less heat than its rating, and below about 35°F it often needs backup heat to make up the difference. On an average winter night here, both of those are already in play.
This isn't a rare cold snap. About 145 nights a year here fall to freezing or below, more than half the nights across the eight months your heat runs. Every one of those nights is below the 35°F and 40°F marks. Only about 7 nights a year reach 0°F, so the deep cold is rare, but the mild-cold range where a standard heat pump loses ground is most of the winter here, not the exception.
A heat pump built to the ENERGY STAR Cold Climate spec is a different machine in this weather. To earn that label it has to deliver at least 1.75 units of heat per unit of electricity at 5°F and hold on to 70 percent of its 47°F capacity at that same temperature, and that's checked by independent testing, not the manufacturer's word. Field testing on prototype cold-climate heat pumps backs this up: over two winters in occupied homes, backup heat covered only a small share of the heat needed between 0°F and 35°F, and the units ran on backup alone only rarely, even near 0°F. If you're looking at a heat pump for a house here, this is the spec that decides whether it keeps up in January or leans on backup heat most of the winter.