What cold nights do to a heat pump here
Winter here is long. The heat runs about eight months a year, October through May, and the overnight low averages 20°F across December, January and February. About 140 nights a year drop to freezing or below, over half the nights the heat is running at all.
A standard heat pump has two marks against it in weather like that. Below 40°F it puts out less heat than its rating says. Below about 35°F it often needs backup heat to keep up. Lenawee County's average winter low of 20°F is under both marks, and every one of those 140 freezing nights is too. This is not a county where a standard heat pump spends most of its time in the range it was rated for.
The nights that reach 0°F or below are rarer, about 7 a year, a small part of the 140 freezing nights. A gas furnace is sized to put out the same heat whether it is 32°F outside or 0°F, so those coldest nights do not change what it can deliver.
There is a real exception on the heat pump side. One built to the ENERGY STAR Cold Climate spec has to prove, under third-party testing, that it still makes at least 1.75 units of heat per unit of electricity at 5°F, and holds onto 70 percent of its 47°F capacity at that same temperature. Field tests of prototype cold-climate heat pumps in occupied homes back that up: backup heat covered only a small share of the load between 0°F and 35°F, and the units rarely ran on backup alone even above 0°F. If a heat pump is going into this county, that is the spec to ask for, not the federal minimum.